6.2.7.1. View Code Sequence (0054,0220)#
Recommended. SHOULD be specified, if known. Only one value is allowed.
The projection of the anatomic region of interest on an image receptor.
Note
Use one of the lateral projections for photographs of the buccal (cheek) region.
Buccal projection is not present in SNOMED-CT, but there are various lateral projections. Buccal (intended site) SCT 763825005 in the anatomic region sequence is enough to specify un-ambiguosly that this photograph is a buccal view.
code scheme designator |
code value |
code meaning |
notes |
---|---|---|---|
SCT |
Frontal projection (qualifier value) |
||
SCT |
Left lateral projection (qualifier value) |
For left buccal photographs |
|
SCT |
Left lateral oblique (qualifier value) |
||
SCT |
Right lateral projection (qualifier value) |
For right buccal photographs |
|
SCT |
Right lateral oblique (qualifier value) |
||
SCT |
Oblique projection (qualifier value) |
||
SCT |
45 degree projection (qualifier value) |
||
SCT |
Oblique lateral (qualifier value) |
||
SCT |
Submentovertical projection (qualifier value) |
Mandatory for EV36 |
|
SCT |
Vertex projection (qualifier value) |
Mandatory for EV37 |
6.2.7.2. View Modifier Code Sequence (0054,0222)#
Photographs in orthodontics are not always taken directly: sometimes there is a device between the patient and the camera lens, like a mirror, to be able to see specific regions.
code scheme designator |
code value |
code meaning |
notes |
---|---|---|---|
SCT |
Mirrored visible image uncorrected |
||
SCT |
Mirrored visible image uncorrected flipped horizontally |
Light from anatomy is reflected on a mirror before reaching camera lens. Image has been flipped horizontally by image acquisition device. |
|
SCT |
Mirrored visible image uncorrected flipped horizontally and vertically |
Light from anatomy is reflected on a mirror before reaching camera lens. Image has been flipped horizontally and vertically by image acquisition device. |
|
SCT |
Mirrored visible image uncorrected flipped vertically |
Light from anatomy is reflected on a mirror before reaching camera lens. Image has been flipped vertically by image acquisition device. |
code scheme designator |
code value |
code meaning |
notes |
---|---|---|---|
SCT |
Close up photographic view of teeth with no set magnification or distance |
||
SCT |
Photographic image corrected intraoral mirrored visible record |
||
SCT |
Mirrored photographic image of teeth corrected flipped horizontally |
||
SCT |
Mirrored photographic image of teeth corrected flipped vertically |
||
SCT |
Mirrored photographic image of teeth corrected flipped vertically and horizontally |
||
SCT |
Photographic image extraoral with 45 degree view |
||
SCT |
Photographic image extraoral with mandible postured forward |
||
SCT |
Photographic image of anterior teeth |
||
SCT |
Photographic image of face with lips in relaxed position |
||
SCT |
Photographic image with lips closed |
||
SCT |
Photographic image with mouth partially opened position and teeth apart |