6.2.7.1. View Code Sequence (0054,0220)#

Recommended. SHOULD be specified, if known. Only one value is allowed.

The projection of the anatomic region of interest on an image receptor.

Note

Use one of the lateral projections for photographs of the buccal (cheek) region.

Buccal projection is not present in SNOMED-CT, but there are various lateral projections. Buccal (intended site) SCT 763825005 in the anatomic region sequence is enough to specify un-ambiguosly that this photograph is a buccal view.

Table CID BBBB. VL View#

code scheme designator

code value

code meaning

notes

SCT

399033003

Frontal projection (qualifier value)

SCT

399173006

Left lateral projection (qualifier value)

For left buccal photographs

SCT

260421001

Left lateral oblique (qualifier value)

SCT

399198007

Right lateral projection (qualifier value)

For right buccal photographs

SCT

260424009

Right lateral oblique (qualifier value)

SCT

399182000

Oblique projection (qualifier value)

SCT

260454004

45 degree projection (qualifier value)

SCT

260427002

Oblique lateral (qualifier value)

Mandatory for IV24, IV25, IV26, IV27

SCT

399255003

Submentovertical projection (qualifier value)

Mandatory for EV36

SCT

260461000

Vertex projection (qualifier value)

Mandatory for EV37

Table CID CCCC. VL Dental View#

code scheme designator

code value

code meaning

notes

SCT

260499007

Occlusal projection (qualifier value)

6.2.7.2. View Modifier Code Sequence (0054,0222)#

Photographs in orthodontics are not always taken directly: sometimes there is a device between the patient and the camera lens, like a mirror, to be able to see specific regions.

Table CID DDDD. VL View Modifier#

code scheme designator

code value

code meaning

notes

SCT

789135000

Mirrored visible image uncorrected

SCT

789134001

Mirrored visible image uncorrected flipped horizontally

Light from anatomy is reflected on a mirror before reaching camera lens. Image has been flipped horizontally by image acquisition device.

SCT

789132002

Mirrored visible image uncorrected flipped horizontally and vertically

Light from anatomy is reflected on a mirror before reaching camera lens. Image has been flipped horizontally and vertically by image acquisition device.

SCT

789133007

Mirrored visible image uncorrected flipped vertically

Light from anatomy is reflected on a mirror before reaching camera lens. Image has been flipped vertically by image acquisition device.

Table CID EEEE. VL Dental View Modifier#

code scheme designator

code value

code meaning

notes

SCT

789131009

Close up photographic view of teeth with no set magnification or distance

SCT

787610003

Photographic image corrected intraoral mirrored visible record

SCT

789310004

Mirrored photographic image of teeth corrected flipped horizontally

SCT

789311000

Mirrored photographic image of teeth corrected flipped vertically

SCT

789312007

Mirrored photographic image of teeth corrected flipped vertically and horizontally

SCT

787612006

Photographic image extraoral with 45 degree view

SCT

787611004

Photographic image extraoral with mandible postured forward

SCT

789313002

Photographic image of anterior teeth

SCT

789314008

Photographic image of face with lips in relaxed position

SCT

787607005

Photographic image with lips closed

SCT

789130005

Photographic image with mouth partially opened position and teeth apart